LTFE Series, Filtered Etch Baths
High
temperature filter etch bath with manual lid or pneumatic slide opening.
FEATURES
- Built for up to
180°C aggressive chemistry.
- Simple
self-contained system.
- Capture complete
advantage of fluoropolymer.
BENEFITS
- Only commercially
proven system to match aggressive chemistry up to 180°C.
- Smooth surge-less
flow from integral filter & centrifugal pump.
- Wetted components of
TFE & PFA fluoropolymer.
ENGINEERING
SPECIFICATIONS
- Chemical
Containment: All plumbing connections, filters and pumps are self
contained in the bath. Provides for additional fail safe containment.
- Clean Up:
Easy clean between process change outs. Flush the system with DI
water or peroxide. Some sites use H2SO4. No scheduled
system flush is prescribed.
- Etch Rate:
Average etch rates in excess of 75 and 85 angstroms per minute have been
reported (temperature and chemical concentration dependent).
- Maximum
Strip Rate Non-uniformity: Reported less than .03 angstroms.
- Minimum
Selectivity: Greater than 18 to 24:1 (nitride to oxide).
- Process
Availability: Reported at 95% to 97% availability per month.
- DI Water
Make Up Control: The system uses a LTFEC-J MTC process controller to
adjust concentrations of DI water. The system adjusts for boiling and
evaporation of the water in the hot phase up to 180° C.
- Flow rates are fine
tuned per installation and to meet your process requirements. Experience shows
an average range of 0 - 200 ml/min.
- DI water is
introduced to the system by a tube located under the inner weir and is mixed
immediately by pump agitation.
- Temperature
Control: A self tuning PID based microprocessor maintains +/- 1°C.
System operations and safety circuits are continuously monitored and displayed
on the LTFEC-J process controller.
- Filter Life:
Current users report filter life span of approximately 3500 - 4500
wafers.
- Filter Size:
1 micron filter, has proven to be the most effective size for Nitride
applications.
- Filter
Housing: Made from PTFE. Integral with pump body. Holds 10" Single
Open End (SOE) cartridge or stacked filter elements. Integral air bleed
standard.
- Safety
Interlock: Cooling water loss, N2 purge loss, internal
motor bi-metal thermal fuse, internal heater thermocouple, bubble style liquid
level sensor.
- Initial Heat
Up: Depending on system size and normal conditions (i.e., proper PID
values open lid, etc.), temperature rise is 1.5-2.0°C per minute.
- 30 to 45 minutes to
reach 50 particles at .5µm size in H2SO4 @ 120°C.
- Tank
Assembly:
Cut out:
w/ Bezel: 15" x 29" (38 x 74 cm)
w/o Bezel: 12-3/4" x 25-1/4" (33x64 cm)
Depth:
w/ Bezel: 15-1/2" (39 cm)
w/o Bezel: 12 1/4" (31 cm)
- Weir inside
dimensions:
For 1 or 2 carriers
4" (100mm) carriers:
11" x 7" x 5-1/2" (29 x 18 x 14 cm)
5" (120mm) carriers:
13" x 7" x 6-1/2" (33x 18x 17 cm)
6" (150mm) carriers:
15" x 7" x 7-1 /2" (38 x 18 x 19 cm)
8" (200mm) carriers:
15-1/2" x 11" x 10-1/4" (39 x 28 x 26 cm)
PUMP AND MOTOR
SPECIFICATIONS
Motor
Specifications
- Totally
Enclosed: Water cooled, permanent shaded pole, grounded motor, purged
labyrinth seal. Exclusive Lufran® design.
- External portion of
the motor is protected by a shroud of fluoropolymer and PVC.
- Top portion of the
motor, cap, motor cooling fittings and the motor power cord are all O- ring
sealed for vapor protection.
- Continuous
service: Compact and totally encapsulated motor is isolated from
aggressive atmosphere. While the motor housing design meets construction
parameters as described for NEC Class 1, Division 1, purged electric motor, it
is not formally listed. Proprietary N2 bearing purge extends life.
Water cooling, and purge patented (4,158,764 4,390,776 - 4,553,024)
- Maintenance:
Usual motor PM cycle is from 6 to 8 months. Two motors are supplied
with new LTFE units for rotation through preventative maintenance.
- Constant cooling
water supply and Nitrogen purge flow will enhance and maintain useful life. Do
not directly immerse motor in media.
Power:
1/2 HP |
Voltage:
120 vac 60 hz
110 vac 50 hz |
RPM:
3400 RPM @ 60 hz
2800 RPM @ 50 hz |
Type:
Shaded Pole |
- Case:
316 stainless steel with cooling channel enclosed in fluoropolymer
and PVC.
- Connection:
Cooling lines 1/8" stainless compression and 1/4" fluoropolymer for N2
- Amp Draw:
9 amp in rush
7 amp maximum
Pump
Specifications
- Type:
Centrifugal.
- Impeller &
Shaft Sleeve: Solid fluoropolymer.
- Max Delivery
Pressure: Up to 15 psi (103 kPa).
- Max Flow:
Up to 18 GPM (68 LPM) with DI water and without filter.
-
Temperatures: Up to 180°C.
For more information on this, or any
other product, please contact our offices and visit our contact
page.